Ultrasonic Anemometer – Integrated Data Logger and Ultra-Low Power: SONIC-ANEMO-DLG-P | LCJ CAPTEURS
The SONIC-ANEMO-DLG-P ultrasonic anemometer features an integrated data logger, ultra-low power consumption and 3 V TTL ASCII output. Ideal for remote weather monitoring stations and OEM applications.
The SONIC-ANEMO-DLG-P is an ultrasonic wind sensor with an integrated data logger, designed to record average wind speed and wind direction. Its ultra-low-power (ULP) design makes it particularly suitable for integration into remote meteorological monitoring stations where energy consumption is a key consideration.
Combining wind measurement and data logging in a lightweight device, the SONIC-ANEMO-DLG-P provides instantaneous wind speed and direction information through a 3 V TTL ASCII interface. The sensor is available in an OEM version or with installation accessories, including a cable, mounting support and fixing flange.
What is the SONIC-ANEMO-DLG-P used for?
The SONIC-ANEMO-DLG-P is designed for wind speed and direction monitoring in meteorological installations, particularly isolated monitoring stations requiring low electrical consumption.
Its integrated data logger records average wind measurements, while the communication interface provides instantaneous wind speed and direction values for integration into compatible monitoring systems.
Advantages
- Integrated data logger: Records average wind speed and wind direction measurements.
- Ultra-low power consumption: Minimum specified consumption of 200 µA at a 1 Hz refresh rate, depending on configuration.
- Ultrasonic wind measurement: Measures wind speed and direction using ultrasonic sensing technology.
- Compact and lightweight: Sensor head weighing approximately 100 g, depending on configuration.
- Flexible integration: Available in Standard and OEM configurations, with mounting accessories.
- Digital communication: ASCII data output through a 3 V TTL interface.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | SONIC-ANEMO-DLG-P |
| Sensor technology | Ultrasonic wind measurement |
| Integrated data logger | Average wind speed and direction recording |
| Output format | ASCII TTL 3 V |
| Transmitted data | Instantaneous wind speed and direction angle |
| Refresh rate* | Up to 1 Hz |
| Wind speed sensitivity | 0.25 m/s |
| Wind speed resolution* | Up to 0.05 m/s |
| Wind speed measurement range | 0.12 to 40 m/s |
| Wind direction sensitivity | ±1.5° |
| Wind direction resolution* | Up to 1° |
| Power supply | 3.0 to 3.6 V DC, regulated |
| Power consumption* | Minimum 200 µA at 1 Hz |
| Operating temperature | -15°C (frost-free) to +55°C |
| Connection | 3 conductors: Tx / Rx / Vref |
| Cable and mounting support* | Depending on Standard / OEM version |
| Weight* | Sensor head: 100 g / Complete assembly: 200 g |
*Specifications may vary depending on project requirements and configuration.
Typical Applications
- Remote meteorological monitoring stations: Wind measurement in isolated locations where low power consumption is important.
- Weather monitoring systems: Acquisition and recording of wind speed and direction data.
- OEM meteorological equipment: Integration of ultrasonic wind sensing into compatible monitoring platforms.
- Low-power environmental monitoring: Wind measurement installations requiring a low-consumption sensor with integrated logging.
What Should You Check Before Choosing the SONIC-ANEMO-DLG-P?
When integrating the SONIC-ANEMO-DLG-P into a monitoring system, several technical parameters should be considered:
- Power supply: The system must provide a regulated voltage between 3.0 and 3.6 V DC.
- Communication interface: Compatibility with the 3 V TTL ASCII output and Tx / Rx / Vref connection must be verified.
- Measurement conditions: The specified operating temperature range applies under frost-free conditions.
- Configuration: The required cable, mounting support and fixing flange should be selected according to the Standard or OEM version.
- Data logging requirements: Recording configuration and data retrieval requirements should be confirmed before integration.
Frequently Asked Questions
What information does the integrated data logger record?
The data logger records average wind speed and wind direction measurements. The communication output provides instantaneous wind speed and direction values.
Is the SONIC-ANEMO-DLG-P suitable for isolated weather stations?
Yes. Its ultra-low-power configuration is specifically intended for integration into isolated meteorological monitoring stations.
Is an OEM version available?
Yes. The sensor is available in an OEM version or with installation accessories, including a cable, mounting support and fixing flange.
Why Choose the SONIC-ANEMO-DLG-P?
The SONIC-ANEMO-DLG-P combines ultrasonic wind measurement, integrated data logging and ultra-low-power operation in a lightweight device.
It is particularly relevant for meteorological monitoring projects requiring both wind data recording and integration into energy-constrained installations. Its Standard and OEM configurations provide options for different installation requirements.
Technical Support from ES Canada