Isotropic E-field probe - 100 kHz to 6 GHz, True RMS: WPF6
zoom_out_map
chevron_left chevron_right
New

Isotropic E-field probe - 100 kHz to 6 GHz, True RMS: WPF6 | Wavecontrol

Isotropic True RMS E-field probe for RF exposure measurements from 100 kHz to 6 GHz, with 0.2 V/m sensitivity, ISO 17025 accredited calibration and compatibility with SMP2, MonitEM and MapEM.

PRICE ON REQUEST

The WPF6 is an isotropic electric field probe designed for broadband RF field measurements from 100 kHz to 6 GHz. It is intended for use with compatible Wavecontrol measurement platforms such as SMP2, MonitEM and MapEM.

Based on True RMS diode technology, the WPF6 provides reliable electric field assessment for RF exposure evaluation, telecom site audits, industrial safety measurements, defence environments and laboratory applications.

Avantages

  • Wide frequency coverage: 100 kHz to 6 GHz for common RF, telecom, broadcast and wireless measurement environments.
  • High sensitivity: measurement capability from 0.2 V/m.
  • Isotropic measurement: suitable for field assessment where signal orientation may vary.
  • True RMS response: designed for accurate broadband exposure measurements.
  • Excellent 50/60 Hz attenuation: attenuation greater than 80 dB, reducing low-frequency interference influence.
  • ISO 17025 accredited calibration: supplied with ILAC-recognized accredited calibration.

Caractéristiques principales

  • Frequency range: 100 kHz – 6 GHz for both WPF6 and WPF6-HP.
  • Sensor type: isotropic sensor based on RMS diode technology.
  • Frequency response type: flat response across the specified operating range.
  • Measurement range, WPF6: 0.2 – 130 V/m in CW mode and 0.2 – 20 V/m in RMS mode.
  • Measurement range, WPF6-HP: 0.2 – 1000 V/m in CW mode and 0.2 – 20 V/m in RMS mode.
  • Dynamic range: 56 dB for WPF6 and 73 dB for WPF6-HP.
  • Sensitivity: 0.2 V/m.
  • Resolution: 0.02 V/m up to 7.5 V/m, then 0.1 V/m from 7.5 V/m to 130 V/m.
  • Frequency response: better than -3 dB at 100 kHz, ±1.5 dB from 250 kHz to 5.5 GHz, and better than -2 dB from 5.5 GHz to 6 GHz.
  • Linearity: ±0.5 dB from 0.5 V/m to 100 V/m.
  • Isotropic deviation: ±0.3 dB at 1 GHz and ±1 dB at 6 GHz.
  • Calibration: ISO 17025 accredited calibration, ILAC recognized.
  • Recommended calibration period: 24 months.
  • Temperature range: -20 °C to 50 °C.
  • Temperature response: +0.1 / -1 dB, related to 20 °C.
  • Dimensions: 28.4 cm x 6 cm Ø.
  • Weight: 95 g.
  • 50/60 Hz attenuation: greater than 80 dB.
  • Compatibility: SMP2, MonitEM and MapEM.

Applications typiques

  • Telecommunications: certification and audit of GSM, 3G, LTE, TDT, AM, FM and WiFi services.
  • Industry: assessment of industrial processes for worker exposure protection.
  • Defence: assessment of military sites and personnel exposure protection.
  • Labs and R&D: RF exposure protection for laboratory and R&D personnel.

Pourquoi choisir WPF6

The WPF6 is a suitable choice when a measurement campaign requires a compact isotropic probe with wide RF coverage, high sensitivity and True RMS measurement. Its flat frequency response and low isotropic deviation make it appropriate for controlled RF exposure assessment across telecom, industrial, defence and laboratory environments.

For higher field levels, the WPF6-HP version extends the CW measurement range up to 1000 V/m, while keeping the same frequency coverage, sensor technology, calibration approach, dimensions and compatibility.

REQUEST A QUOTE