Electric and magnetic field probe - isotropic True RMS measurement from 1 Hz to 400 kHz: WP400 | Wavecontrol
The WP400 is a low-frequency electromagnetic field probe designed for electric and magnetic field measurement from 1 Hz to 400 kHz.
The Wavecontrol WP400 is an isotropic probe for measuring low-frequency electric and magnetic fields from 1 Hz to 400 kHz. It connects to Wavecontrol SMP3 and SMP2 field meters for broadband True RMS measurements, frequency-selective analysis and electromagnetic field exposure assessments.
Product video
In this video, Wavecontrol introduces the WP400 as one of the electric and magnetic field probes compatible with the SMP2 field meter. Playback starts at the section on these probes.
Advantages
- Isotropic measurement provides a total field reading and individual readings for each axis.
- FFT spectrum analysis identifies the frequencies present in the total field and on each axis.
- Weighted Peak Method displays the result as a percentage of the selected exposure limit.
- Accredited calibration is supplied under ISO/IEC 17025.
Main features
- Part number — WWP1001.
- Sensor — patented design with isotropic 100 cm² coils and embedded electrodes.
- Broadband electric field range — 1 V/m to 100 kV/m.
- Broadband magnetic field range — 50 nT to 30 mT at 50 Hz and 50 nT to 10 mT from 100 Hz to 10 kHz.
- FFT electric field range — 4 mV/m to 100 kV/m up to 80 kHz. Above 80 kHz and up to 400 kHz, the range is 4 mV/m to 47 kV/m.
- FFT magnetic field range — 0.5 nT to 30 mT at 50 Hz and 0.5 nT to 10 mT from 100 Hz to 10 kHz. The upper magnetic field limit varies with frequency in both measurement modes.
- Spectral resolution — 1 Hz, 10 Hz, 100 Hz or 1 kHz, depending on the selected span. The FFT uses 1,024 points, with a sampling rate of 1.024 MHz.
- Isotropy — ±1% for the electric field and ±0.5% for the magnetic field.
- Dimensions and weight — 280 mm long, 128 mm in diameter and 425 g.
- Recommended calibration interval — 24 months.
Typical applications
- Power utilities — field surveys at substations and near high-voltage power lines.
- Railway environments — exposure measurements on trains and around rail infrastructure.
- Industrial workplaces — worker exposure assessments near welding equipment and low-frequency induction heating systems.
- RFID and electronic article surveillance — field measurements around readers and detection gates.
Why choose the Wavecontrol WP400?
When several low-frequency sources contribute to exposure at a site, use the broadband reading to survey each measurement point, then switch to FFT to identify the dominant frequency components at that location. Both measurements can be made with the same probe and field meter.